HVDC & VSC Converter Valve Capacitors
In an HVDC or VSC station, the highest-voltage capacitor positions are valve grading, thyristor snubber, RC dividers and DC filter damping. HVC supplies these as screw-terminal ceramic discs from 10 kV to 150 kV, 100 pF to 30,000 pF, N4700 Class I dielectric, screened to partial discharge ≤ 5 pC at rated voltage.
High voltage direct current transmission moves bulk power over distances and submarine routes where AC cannot compete. Whether the converter uses line-commutated thyristors (LCC) or voltage-source IGBT modules (VSC, including MMC), the valve needs capacitors that hold a defined value under DC stress, pass partial-discharge screening, and survive decades of thermal cycling.
This page is written for three buyers outside the original valve OEM: engineers qualifying a المصدر الثاني for an existing design, maintenance teams sourcing replacement spares for installed valves, and manufacturers of impulse and partial-discharge test equipment.

Screw-terminal doorknob capacitor, 40 kV / 2000 pF, N4700, M5 stud.
What the valve position actually specifies
- Rated DC voltage 10 kV to 150 kV, capacitance 100 pF to 30,000 pF
- N4700 Class I dielectric, −40 °C to +125 °C, 10,000 MΩ insulation resistance
- Partial discharge screened to ≤ 5 pC at rated voltage, unit by unit
- Hi-pot at 150%–200% of rated voltage before shipment
- Single or double disc, stud M4 / M5 / 8-32 UNC, built to drawing
مجموعة كاملة: screw-terminal doorknob capacitors, 203 catalogue models.
Where capacitors sit in an HVDC or VSC converter station
Each position has its own voltage class, capacitance band and failure consequence. The table below maps the six positions that appear in a converter station to the component family that serves them.
| الموقع الحالي | الجهد النموذجي | الوظيفة | عائلة المكونات |
|---|---|---|---|
| Valve grading (thyristor levels) | 10-100 كيلو فولت | Divides DC and impulse stress evenly across series-connected devices | Screw-terminal ceramic disc، N4700 |
| Thyristor RC snubber | 10-100 كيلو فولت | Limits dv/dt and reverse-recovery overshoot at turn-off | Screw-terminal ceramic disc، N4700 |
| RC or capacitive divider | 10-150 كيلو فولت | Reference for voltage measurement and protection | Screw-terminal ceramic + مقاوم ذو طبقة سميكة |
| DC filter damping | 10-50 كيلو فولت | Damps resonance in DC-side filter banks | Screw-terminal ceramic disc |
| Gate-drive and auxiliary supplies | 0.7-3 كيلو فولت | Snubber and DC-link support in the low-voltage electronics | Metallized polypropylene film (DTS) |
| MMC submodule DC link | 2–6 kV, millifarad | Energy buffer per submodule | Not supplied by HVC |
Why Class I ceramic is specified at valve level
A valve grading or snubber capacitor is selected on what it does at rated DC voltage, not on its catalogue capacitance. Four parameters decide whether a part survives in a valve hall.
- Partial discharge at rated voltage. HVC N4700 screw-terminal parts are screened to ≤ 5 pC at rated voltage. A void that discharges at operating voltage erodes the dielectric from the inside; the capacitance reading stays inside tolerance until the part fails.
- Dielectric strength margin. Every unit is hi-pot tested at 150%–200% of rated voltage, so the DC stress in service sits well below the tested breakdown level.
- Capacitance stability over temperature. N4700 is a Class I dielectric with a defined, repeatable temperature coefficient and −40 °C to +125 °C operating range, so the grading ratio does not drift with valve-hall temperature.
- مقاومة العزل. 10,000 MΩ keeps the DC leakage contribution negligible against the parallel grading resistor chain.
Voltage classes and capacitance ranges supplied
Screw-terminal ceramic discs, N4700 / Y5T / Y5V, single or double disc, M4 / M5 / 8-32 UNC stud.
| الفولطية | نطاق السعة |
|---|---|
| 10 كيلو فولت العاصمة | 560 بيكوفاراد - 20,000 بيكوفاراد |
| 15 كيلو فولت العاصمة | 250 بيكوفاراد - 10,000 بيكوفاراد |
| 20 كيلو فولت العاصمة | 200 بيكوفاراد - 10,000 بيكوفاراد |
| 30 كيلو فولت العاصمة | 190 بيكوفاراد - 5,900 بيكوفاراد |
| 40 كيلو فولت العاصمة | 100 بيكوفاراد - 15,000 بيكوفاراد |
| 50 كيلو فولت العاصمة | 100 بيكوفاراد - 8,000 بيكوفاراد |
| 60 كيلو فولت العاصمة | 500 بيكوفاراد - 4,000 بيكوفاراد |
| 70 كيلو فولت العاصمة | 10,000 الجبهة الوطنية |
| 80 كيلو فولت العاصمة | 2,000 بيكوفاراد - 5,000 بيكوفاراد |
| 100 كيلو فولت العاصمة | 500 بيكوفاراد - 3,000 بيكوفاراد |
| 120 كيلو فولت العاصمة | 1,000 الجبهة الوطنية |
| 150 كيلو فولت العاصمة | 800 الجبهة الوطنية |
Values above the listed band, non-standard stud threads and double-disc stacks are built to drawing. Send the voltage, capacitance, tolerance, body envelope and stud specification.
Representative part numbers
One part per voltage class, each linking to its specification page. The catalogue covers 203 doorknob models; values outside the bands above are built to drawing.
| رقم القطعة | الجهد االكهربى | مواسعة | عازل | Body / stud |
|---|---|---|---|---|
| HVCT8G-10KV-DL30-561K | 10 كيلو فولت | 560 الجبهة الوطنية | N4700 | D30 × H15, M4 |
| HVCT8G-20KV-DL30-201K | 20 كيلو فولت | 200 الجبهة الوطنية | N4700 | D30 × H17, M4 |
| HVCT8G-30KV-DL50-222K | 30 كيلو فولت | 2200 الجبهة الوطنية | N4700 | D50 × H20, M4 |
| HVCT8G-40KV-DL55-202K | 40 كيلو فولت | 2000 الجبهة الوطنية | N4700 | D55 × H25, M5 |
| HVCT8G-50KV-DL80-502M | 50 كيلو فولت | 5000 الجبهة الوطنية | N4700 | D80 × H75, M5 |
| HVCT8G-100KV-DL60-501K | 100 كيلو فولت | 500 الجبهة الوطنية | N4700 | D60 × H39, M5 |
Tolerance K (±10%) or M (±20%); other tolerances on request. Every part is quoted with its partial-discharge test record.
مسار التأهيل
Converter valve programmes normally run the candidate part through four stages before it enters the approved list. HVC supports each stage with documentation:
| المرحلة | What the customer measures | What HVC supplies |
|---|---|---|
| 1. Datasheet review | Voltage, capacitance, tolerance, body size, stud | Datasheet with drawing and part-number decoding |
| 2. Incoming sample test | Capacitance, DF, IR, hi-pot, partial discharge | PD screening data and hi-pot records |
| 3. Environmental qualification | Temperature cycling, damp heat, long-term voltage | 1000-hour life test reports |
| 4. مؤهلات المورد | ISO 9001 QMS, traceability, change notification | ISO 9001:2015 certificate, batch traceability |
Most converter programmes start under NDA because the specification discloses valve topology and operating margins. HVC signs customer NDAs and works under them for drawing-level data exchange.
Film capacitors for auxiliary circuits
The low-voltage electronics around the valve, including gate-drive supplies and IGBT snubbers in auxiliary converters, take metallized polypropylene film rather than ceramic. The HVC DTS series covers 700–3000 Vdc, 0.0068–5.6 µF, self-healing polypropylene metallized film, in six voltage classes. View the film capacitor range.
Replacement spares for installed valves
Installed converter valves stay in service for decades while the original capacitor supplier changes ownership, discontinues the body size, or moves the part to a different plant. The valve position still needs a part with the same body envelope, stud thread and capacitance, because the grading ratio and the mechanical fit are fixed by the existing hardware.
HVC builds to the original drawing and supplies a cross-reference table with the offer. Send the original part number, the drawing or the datasheet page, the annual spare quantity and the required acceptance test. For retrofit campaigns we quote matched sets so a single valve level is replaced from one production batch.
- Same body diameter, height and stud thread (M4, M5, 8-32 UNC)
- Capacitance and tolerance matched to the original drawing, not to a nearest catalogue value
- Partial-discharge screening per unit, with the test record supplied
- Batch-matched sets for multi-unit valve levels
Capacitors for impulse and partial-discharge test equipment
Impulse voltage generators, DC hipot sets and partial-discharge test benches load their capacitors very differently from a converter valve: short, high-current pulses at low repetition rate, followed by long idle periods. The selection criteria are peak current, stored energy per shot and mechanical mounting, not continuous ripple current.
| Test-set position | ما يؤكد عليه | المواصفات للتأكيد |
|---|---|---|
| Impulse generator stage capacitor | Peak discharge current, mechanical shock | Capacitance, rated DC, stud and body, PD at rated voltage |
| DC hipot divider | Long-term DC stress, leakage stability | Insulation resistance, capacitance stability over temperature |
| PD test coupling capacitor | Background noise floor | PD level at rated voltage, low loss, stable capacitance |
For laboratory and university benches the same parts serve Marx generators, capacitor banks and pulsed-power experiments. Single-unit and small-lot orders are accepted because the requirement is usually one specific voltage and capacitance.
الأسئلة المتكررة
What voltage class do HVDC valve grading capacitors use?
Valve grading and snubber positions in LCC valves typically sit in the 10–100 kV band, with dividers reaching 150 kV. HVC covers 10 kV to 150 kV in screw-terminal ceramic disc form.
Why does partial discharge matter more than capacitance tolerance here?
Because a discharge inside the dielectric grows under DC stress while the capacitance reading stays in tolerance. Screening every unit to ≤ 5 pC at rated voltage removes the parts that would fail in service; capacitance tolerance alone does not.
Can a Class II disc replace a Class I part in a valve?
Not for grading or snubber duty. Class II dielectrics lose capacitance with DC bias, temperature and age, which changes the grading ratio across the thyristor string. N4700 Class I holds its value over −40 °C to +125 °C.
What capacitance is available at 40 kV?
100 pF to 15,000 pF in standard bodies, with larger values built to drawing. 40 kV is the most widely specified class in the HVC screw-terminal range.
Do you work under NDA?
Yes. Converter and defence programmes normally start with a mutual NDA before drawings and operating margins are exchanged.
Can you match a discontinued Murata or TDK screw-terminal part?
Yes, when the original drawing or datasheet is available. HVC supplies the cross-reference table and the replacement part number with the quotation.
Can you supply spares for a valve that is already in service?
Yes. Send the original part number or drawing and the annual spare quantity. We quote matched sets so one valve level is replaced from a single production batch, with the partial-discharge record per unit.
Do you supply capacitors for impulse generators and PD test sets?
Yes. Single units and small lots are accepted. Tell us the stage voltage, capacitance, peak discharge current and mounting, and we return the part number with the PD and hi-pot test data.
Send the voltage class, capacitance, tolerance, body envelope, stud and annual quantity. HVC replies with a matching part number, partial-discharge screening data and a 1000-hour life report. NDA on request.
طلب عرض أسعار فني →