آلة حاسبة هندسية
Cockcroft-Walton Multiplier Calculator
كيفية قراءة الرسم التخطيطي. C1, C3 and C5 are the pump capacitors on the AC side; C2, C4 and C6 are the smoothing capacitors; D1 to D6 are the rectifier chain that hands charge from one stage to the next. The DC output is taken across the smoothing column, so three stages give 2 × 3 × Vpk at no load, and n stages give 2 × n × Vpk.
A Cockcroft-Walton multiplier adds the AC peak once per stage, so n stages reach 2 × n × Vpk with nothing connected to the output. As soon as the load draws current, the stage capacitors partly discharge between cycles: the output sags by a voltage drop that grows with the cube of the stage count, and it carries a peak-to-peak ripple. This calculator returns the no-load output, that drop, the ripple, the loaded output and the effective output capacitance, so you can see whether the stage count and capacitance you picked still hold at the current you need.
المدخلات
النتائج
Model: full-wave cascade, C = capacitance of one capacitor per stage, f = AC frequency in Hz, I = DC load current.
- No-load output
- -
- انخفاض الجهد
- -
- Ripple (p-p)
- -
- Output under load
- -
- Effective output C
- -
الصيغة
No-load V0 = 2 × n × Vpk. Drop ΔV = (I / (f × C)) × (2n³/3 + n²/2 − n/6). Ripple δV = (I / (f × C)) × n(n+1)/2. Output under load = V0 − ΔV. Example: 6 stages, 10 kV peak, 1 nF per stage, 50 kHz and 1 mA gives 120 kV no-load, 3.22 kV drop and 116.8 kV loaded.
ما لا تتضمنه الآلة الحاسبة
- Diode drops. Each stage loses forward voltage; with 6 stages that is 12 V, negligible at 100 kV and significant at 2 kV.
- Stray capacitance. Capacitance to ground and to the tank adds ripple the formula does not include.
- Frequency limit. Above roughly 100 kHz diode recovery and loop inductance dominate, and the formula overstates the output.
اختيار الأجزاء
Multiplier capacitors are Class 1 N4700 so the stages divide evenly: radial disc for compact stages, طرفية لولبية above 40 kV. Diodes are on the rectifier page.
Send the calculated values and the duty: request a technical quoteالرد خلال 6 ساعة.